Case Reports

doi: 10.25005/2074-0581-2019-21-2-347-350
CHIMNEY-GRAFT TECHNIQUE TO TREAT A TYPE IA ENDOLEAK AFTER A PREVIOUS EVAR

Egan L. Kalmykov, Wael Ahmad, Payman Majd, Jan S. Brunkwal

Department of Vascular and Endovascular Surgery, University Hospital of Cologne, Cologne, Germany

A 73 year old man who underwent an elective EVAR procedure in 2014 for an infrarenal AAA presented two years later with a type IA endoleak. The CTA showed a distal migration of the proximal part of the stent graft resulting in a type IA endoleak. In order to treat this new diagnosed endoleak an endovascular repair using chimney technique (with a snorkel-stent graft in the renal artery-bilaterally) with proximal extension of sealing zone with an endovascular aortic cuff has been undergone with implantation of a stent graft in the right renal artery as a periscope and a chimney in the left renal artery. Subsequently, an Endurant II Aortic Cuff was implanted. The whole procedure was performed using CO2  instead of iodinated contrast medium. In the 5 month follow-up with abdominal ultrasonography no endoleak could be identified with stabilization of aneurysmal sac diameter. The use of chimney technique adds an additional tool to the armamentarium of endovascular surgeon to deal with the complex type IA endoleaks

Keywords: Abdominal aneurysm , CO2 angiography , chimney-graft technique, type IA endoleak, periscope technique.

Download file:


References
  1. Gawenda M, Brunkwall J. Ruptured abdominal aortic aneurysm: the state of play. Dtsch Arztebl Int. 2012;109(43):727-32. Available from: http:// dx.doi.org/10.3238/arztebl.2012.0727.
  2. Torsello G, Troisi N, Tessarek J, Torsello GF, Dorigo W, Pulli R, et al. Endovascular aortic aneurysm repair with the Endurant stent-graft: early and 1-year results from a European multicenter experience. J Vasc Interv Radiol. 2010;21(1):73-80. Available from: http://dx.doi.org/10.1016/j. jvir.2009.09.021.
  3. Singh MJ, Fairman R, Anain P, Jordan WD, Maldonaldo T, Samson R, et al. Endurant U.S. Pivotal Trial Investigators. Final results of the Endurant Stent Graft System in the United States regulatory trial. J Vasc Surg. 2016;64(1):55-62. Available from: http://dx.doi.org/10.1016/j. jvs.2015.12.048.
  4. Kouvelos G, Koutsoumpelis A, Lazaris A, Matsagkas M. Late open conversion after endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2015;61(5):1350-6. Available from: http://dx.doi.org/10.1016/j. jvs.2015.02.019.
  5. Калмыков ЕЛ, Садриев ОН. Поздние конверсии после эндопротезирования аневризм брюшной аорты. Ангиология и сосудистая хирургия. 2016;22(3):168-75. Kalmykov EL, Sadriev ON. Pozdnie konversii posle endoprotezirovaniya anevrizm bryushnoy aorty [Late conversions after AAA endografting]. Angiologiya i sosudistaya khirurgiya. 2016;22(3):168-75.
  6. Antoniou GA, Georgiadis GS, Antoniou SA, Neequaye S, Brennan JA, Torella F, et al. Late rupture of abdominal aortic aneurysm after previous endovascular repair: a systematic review and meta-analysis. J Endovasc Ther. 2015;22(5):734-44. Available from: http://dx.doi. org/10.1177/1526602815601405.
  7. Verzini F, Isernia G, De Rango P, Simonte G, Parlani G, Loschi D, et al. Abdominal aortic endografting beyond the trials: a 15-year single-center experience comparing newer to older generation stent-grafts. J Endovasc Ther. 2014;21(3):439-47. Available from: http://dx.doi.org/10.1583/13- 4599MR.
  8. Stokmans RA, Teijink JA, Forbes TL, Böckler D, Peeters PJ, Riambau V, et al. Early results from the ENGAGE registry: real-world performance of the Endurant Stent Graft for endovascular AAA repair in 1262 patients. Eur J Vasc Endovasc Surg. 2012;44(4):369-75. Available from: http://dx.doi. org/10.1016/j.ejvs.2012.07.005.
  9. Mangialardi N, Orrico M, Ronchey S, Praquin B, Alberti V, Setacci C. Towards an entirely endovascular aortic world: an update of techniques and outcomes for endovascular and open treatment of type I, II, and III endoleaks. J Cardiovasc Surg (Torino). 2016;57(5):698-711.
  10. Pecoraro F, Corte G, Dinoto E, Badalamenti G, Bruno S, Bajardi G. Cinical outcomes of Endurant II stent-graft for infrarenal aortic aneurysm repair: comparison of on-label versus off-label use. Diagn Interv Radiol. 2016;22(5):450-4. Available from: http://dx.doi.org/10.5152/ dir.2016.15418.
  11. Antoniou GA, Georgiadis GS, Antoniou SA, Kuhan G, Murray D. A metaanalysis of outcomes of endovascular abdominal aortic aneurysm repair in patients with hostile and friendly neck anatomy. J Vasc Surg. 2013;57(2):527-38. Available from: http://dx.doi.org/10.1016/j. jvs.2012.09.050.
  12. Troisi N, Torsello G, Donas KP, Austermann M. Endurant stent-graft: a 2-year, single-center experience with a new commercially available device for the treatment of abdominal aortic aneurysms. J Endovasc Ther. 2010;17(3):439-48. Available from: http://dx.doi.org/10.1583/10-3090.1.
  13. Bastos Goncalves F, Hoeks SE, Teijink JA, Moll FL, Castro JA, Stolker RJ, et al. Risk factors for proximal neck complications after endovascular aneurysm repair using the Endurant stentgraft. Eur J Vasc Endovasc Surg. 2015;49(2):156-62. Available from: http://dx.doi.org/10.1016/j. ejvs.2014.10.003.
  14. Montelione N, Pecoraro F, Puippe G, Chaykovska L, Rancic Z, Pfammatter T, et al. A 12-year experience with chimney and periscope grafts for treatment of type I endoleaks. J Endovasc Ther. 2015;22(4):568-74. Available from: http://dx.doi.org/10.1177/1526602815586972.
  15. Donas KP, Telve D, Torsello G, Pitoulias G, Schwindt A, Austermann M. Use of parallel grafts to save failed prior endovascular aortic aneurysm repair and type IA endoleaks. J Vasc Surg. 2015;62(3):578-84. Available from: http://dx.doi.org/10.1016/j.jvs.2015.04.395.
  16. Mylonas SN, Moulakakis KG, Kakisis JD, Brountzos EN, Liapis CD. New chimney after chimney EVAR for the treatment of type IA endoleak. Int J Angiol. 2016;25(5):e126-e130. Available from: http://dx.doi. org/10.1055/s-0035-1556055.

Authors' information:


Egan L. Kalmykov,
MD, PhD, Department of Vascular and Endovascular Surgery, University Hospital of Cologne ORCID ID: 0000-0001-6784-2243

Wael Ahmad,
MD, Department of Vascular and Endovascular Surgery, University Hospital of Cologne ORCID ID: 0000-0001-5090-3468

Payman Majd,
MD, Department of Vascular and Endovascular Surgery, University Hospital of Cologne ORCID ID: 0000-0002-1093-8962

Jan S. Brunkwall,
Professor, MD, PhD, Department of Vascular and Endovascular Surgery, University Hospital of Cologne ORCID ID: 0000-0003-3082-6009

Conflicts of interest: No conflict

Address for correspondence:


Egan L. Kalmykov
MD, PhD, Department of Vascular and Endovascular Surgery, University Hospital of Cologne

50937, Germany, Cologne, Kerpener str., 62

Tel.: +49 (1766) 1533534

E-mail: egan0428@mail.ru